Titebond GREENchoice Fast Grab FRP Adhesive is a high-quality, VOC-compliant, adhesive specifically formulated for the installation of FRP (fiber-reinforced plastic) panels. Its fast grab and bonding power greatly reduce the need for extended bracing. GREENchoice Fast Grab FRP is environmentally superior and contains no ozone-depleting chemicals. Unlike solvent-based adhesives, it is nonflammable, emits no harmful fumes and cleans up with water. Meets GreenSeal GS-36, LEED, SCAQMD, CARB and NAHB Green Building specifications. FDA and Canadian Food Inspection Agency (CFIA) approved for indirect food contact. |
Type Proprietary emulsion polymer | Reactive VOC 2.6 g/L |
State Low viscosity mastic | Weight/gallon 11.6 lbs. |
Color Light beige | Flashpoint > 200°F. |
Solids 67% | Freeze/thaw stability Stable |
Viscosity 100,000 cps | pH 5.0 |
Storage life Up to 2 years in unopened container |
50 sq. ft. per gallon |
Application Temperature Over 50°F and below 90°F for adhesive and substrates.
Service Temperature Range 0°F. to 110°F.
Method of Application The optimal trowel for best overall performance and coverage is a v-notch trowel, 3/16” wide x 1/4” deep, spaced 1/2” c.c. Trowels using dimensions other than the optimal size can be used, but they may affect working time and coverage. For additional trowel recommendations, please contact Franklin Technical Service at 1.800.347.4583.
Coverage 50 sq. ft. per gallon.
Working Time 20 minutes at 70°F.
Working Surfaces Surfaces must be dry and free of any material that may deter adhesion, including severe and thick amounts of drywall joint compound. Patch large holes and depressions and remove any bumps or high spots, dust, oil, and grease. Concrete surfaces must be well cured and completely dry. Cut and pre-fit all panels. Lay fiberglass panels flat and let them acclimate to room temperature 24 hours before installing.Note: Panels used in conjunction with channel moldings should NOT fit tightly into the moldings. Leave a small gap under the molding for expansion and follow panel manufacturer’s recommendations. Any holes drilled through the panels for fasteners, pipes or conduits should be oversized to allow for natural movement of the panel. Click for FRP Installation Guide.
Cleanup Tools and excess adhesive may be cleaned with water while wet. If adhesive has dried, use mineral spirits. Follow solvent vendor's precautions when using solvents. NOTE: Test solvent in an out-of-the-way area to make sure it will not mar or attack the surface.
FRP Installation Guide |
For best results, store GREENchoice Fast Grab FRP Adhesive above 50°F. Do not use over treated plywood or metal, plastic, foam board, painted surfaces, sealed concrete, certain types of specially treated or moisture resistant gypsum wallboard, or other non-porous surfaces. For these substrates, for use on freezers, and any other application other than FRP, call Technical Service at 1-800-347-4583. KEEP FROM FREEZING.
CAUTION: EYE AND SKIN IRRITANT. Do not swallow. Do not allow eye contact or prolonged skin contact. FIRST AID: If swallowed, do not induce vomiting; contact physician. If eye contact occurs, flush eyes with water for 15 minutes. Wash skin contact areas with soap and water. If irritation from eye or skin contact areas persists, contact physician. For additional information, refer to Material Safety Data Sheet. KEEP OUT OF THE REACH OF CHILDREN.
Part No. |
Size |
Weight |
Units Per Package |
Packages Per Pallet |
4054 |
4 Gallon Pail |
50.58 |
1 |
36 |
4056 |
Gallon Pail |
24.70 |
2 |
75 |